Fluke 117 Multimeter

The Fluke 117 Multimeter is perfect for use in the field for any electrical measurements you may need to take. ย It features Fluke's VoltAlertโ„ข which allows for non-contact voltage detection. ย The Fluke 117 will also automatically select either AC/DC voltage. ย It also has a feature which allows you to see the Min/Max/Average with the elapsed time.

The Fuke 117 is CAT III 600 V safety rated. ย It has a compact design that allows you to easily use it with one hand. ย It is capable of measuring up to 10A along with voltage, resistance, continuity, frequency, and capacitance.

Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010โ€“1 600 VCAT III, Pollution Degree 2
Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10ยฐC to +50ยฐC
Storage temperature -40ยฐC to +60ยฐC
Battery type 9 volt Alkaline, NEDA 1604A / IEC 6LR61
Battery life 400 hours typical, without backlight
Accuracy Specifications
DC millivolts Range/resolution 600.0 mV / 0.1 mV
Accuracy ยฑ([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ยฑ([% of reading] + [counts]): 0.5% + 2
Auto volts Range/resolution 600.0 V / 0.1 V
Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivoltsยน True RMS Range/resolution 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC voltsยน True RMS Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution 600 ฮฉ / 1 ฮฉ
Accuracy Beeper on < 20 ฮฉ, off > 250 ฮฉ detects opens or shorts of
500 ฮผs or longer.
Ohms Range/resolution 600.0 ฮฉ / 0.1 ฮฉ
6.000 kฮฉ / 0.001 kฮฉ
60.00 kฮฉ / 0.01 kฮฉ
600.0 kฮฉ / 0.1 kฮฉ
6.000 Mฮฉ / 0.001 Mฮฉ
Accuracy 0.9% + 1
Range/resolution 40.00 Mฮฉ / 0.01 Mฮฉ
Accuracy 5% + 2
Diode test Range/resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance Range/resolution 1000 nF / 1 nF
10.00 ฮผF / 0.01 ฮผF
100.0 ฮผF / 0.1 ฮผF
9999 ฮผF / 1 ฮผF
100 ฮผF to 1000 ฮผF
Accuracy 1.9% + 2
Range/resolution > 1000 ฮผF
Accuracy 5% + 20%
Lo-Z capacitance Range 1 nF to 500 ฮผF
Accuracy 10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz) Range/resolution 6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy 1.5% + 3
20 A continuous overload for 30 seconds max
DC amps Range/resolution 6.000 A / 0.001 Aย ย  10.00 A / 0.01 A
Accuracy 1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)ยฒ Range/resolution 99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2

 